SAR triggering configuration structure.
Data Fields | |
uint32_t | pwrUpDelay |
Power up delay for SAR blocks in Deep Sleep Clock cycles. More... | |
uint32_t | scanCount |
Configures the number of samples SAR will take when triggered. More... | |
uint32_t | simultControl |
Configures the SAR ADCs for simultaneous control. More... | |
uint32_t | simultTrigSource |
Configures the trigger source for simultaneous SAR hardware trigger. More... | |
cy_en_sar_simult_trig_event_sel_t | simultTrigEvent |
Configures simultaneous trigger signal event. | |
cy_en_sar_simult_trig_sync_sel_t | simultTrigSync |
Enables synchronization of trigger signal. | |
cy_en_sar_simult_trig_sample_sel_t | simultSamplesPerTrigger |
Configures scan sampling mode for each trigger event. | |
cy_en_sar_simult_trig_intr_sel_t | simultEOSIntrSelect |
Configures EOS interrupt condition. | |
uint32_t cy_stc_sar_common_config_t::pwrUpDelay |
Power up delay for SAR blocks in Deep Sleep Clock cycles.
Range 0..255.
uint32_t cy_stc_sar_common_config_t::scanCount |
Configures the number of samples SAR will take when triggered.
Range 1..256.
uint32_t cy_stc_sar_common_config_t::simultControl |
Configures the SAR ADCs for simultaneous control.
The value is a combined mask, created using following macros:
uint32_t cy_stc_sar_common_config_t::simultTrigSource |
Configures the trigger source for simultaneous SAR hardware trigger.
Use one of the following values: