Test selection bitmask values

General Description

Macros

#define SELFTEST_IPC_PPCA_LOCK   (0x01U)
 Acquire / lock-status / Release (sub-tests 1, 2, 3)
#define SELFTEST_IPC_PPCA_DATA   (0x02U)
 DATA0/DATA1 write/read integrity and independence (sub-tests 4, 5, 13)
#define SELFTEST_IPC_PPCA_NOTIFY   (0x04U)
 Notify-to-self loopback and INTR clear-on-write-1 (sub-tests 6, 7, 14)
#define SELFTEST_IPC_PPCA_INTR   (0x08U)
 Interrupt masking, INTR_MASKED consistency, INTR_SET (sub-tests 8, 9, 10)
#define SELFTEST_IPC_PPCA_RELEASE_EVT   (0x10U)
 Release-event self-loopback (sub-test 11)
#define SELFTEST_IPC_PPCA_SILENT_REL   (0x20U)
 Silent release, no interrupt generated (sub-test 12)
#define SELFTEST_IPC_PPCA_ALL   (0x3FU)
 All six groups combined.