ModusToolbox Safety Test Library
Loading...
Searching...
No Matches

General Description

Macros

#define NUMBER_OF_TIMER_TICKS_LO   (9u)
 Lower possible interrupt count.
#define NUMBER_OF_TIMER_TICKS_HI   (15u)
 Higher possible interrupt count.
#define INTERRUPT_TEST_TIME   (1000u)
 Interrupt test period.

Macro Definition Documentation

◆ NUMBER_OF_TIMER_TICKS_LO

#define NUMBER_OF_TIMER_TICKS_LO   (9u)

Lower possible interrupt count.

  • PSOC 4 devices: 9u
  • PSOC 61 Programmable Line, PSOC 62 Performance Line, PSOC Control C3, XMC7000, and XMC5000 devices: 22u for configurations where the timer input clock and period produce about 22 to 27 terminal- count interrupts in 1000 us; 22u is the low end of that fixed pass window

◆ NUMBER_OF_TIMER_TICKS_HI

#define NUMBER_OF_TIMER_TICKS_HI   (15u)

Higher possible interrupt count.

  • PSOC 4 devices: 15u
  • PSOC 61 Programmable Line, PSOC 62 Performance Line, PSOC Control C3, XMC7000, and XMC5000 devices: 27u for configurations where the timer input clock and period produce about 22 to 27 terminal- count interrupts in 1000 us; 27u is the high end of that fixed pass window